Regulator

Yes, an adjustable one, plus a line gauge.

Most Thai "high-pressure" regulators are fixed at about 26–35 psi. The Lucky Flame L-323 adjusts 0–2.2 kg/cm² (0–31 psi), has a hose-burst shut-off and is rated 5 kg/h (about 64 kW). Add a 0–2 bar gauge after it so you can repeat a flame setting.

Flashback arrestor

Not needed for this burner. Fit other safety parts.

Gas and air only mix under the blanket, so a flame has no mixture to travel back through. Arrestors are for oxy-fuel and pre-mixed burners. Some can pass this flow, so you can fit one as an extra, but spend the money on an emergency shut-off valve and a flame-failure valve first. Options below.

Pipe

20-bar LPG hose on the ground, copper up the riser.

NCR 20-bar LPG hose (มอก.) in black conduit from the regulator to the foot of the dome, two clamps on every barb. Copper from there up to the bowl, because of the heat. 1/4" copper passes about 54 kW at 10 psi; 3/8" about 2.5 times that. See the chart.

Condensate line

No line. Fit a drip leg at the low point, and no drain before the regulator.

Gas can turn back to liquid after the regulator on a cold night, especially at 20 psi with a low cylinder. A tee with a capped stub at the lowest point (about ฿150) catches any liquid and dirt. How to build it. Why nothing goes before the regulator.

Water bath

Yes. It's the biggest single improvement.

Boiling LPG chills the cylinder, and pressure drops with it. Two 15 kg cylinders in air hold a 50 kW flame for about 1 hour on a cool night. Standing in a tub of water, they hold it all night. Use plain or warm water, never heated, with the valves above the water.

Disconnect at the bowl

Metal flare union at the bowl, quick coupler lower down.

Fit a ball valve and brass flare union at the bowl, because they survive the heat. Fit a self-sealing quick coupler about 1 m down on a braided hose, out of the heat, for fast removal.

Flashback arrestors and other safety options

A flashback arrestor stops a flame travelling back up a pipe. It only matters if there's a burnable gas and air mix in the pipe. This line holds pure gas, so flame has nothing to burn in there unless air gets in, for example after a disconnect.

Flashback optionWhat it isGood and badOur view
No arrestorPurge the line with gas after any disconnect, away from flameSimple, with no flow loss or extra joints. Relies on following the routine.Fine for this burner, with the safety parts below
Welding arrestor at the regulatorSUMO ARG-L 3/8", for welding gas, sold at HomeProEasy to find. Thread is for welding fittings, so it needs adaptors. Flow at your pressure isn't published on the listing.Only if the maker confirms the flow below
Industrial inline arrestorWitt 85-30, with LPG listed as a suitable gasA proper part with flow charts. Costs more, may need importing, and needs its flow re-tested yearly.Best choice if you want one
The flow to ask for: a 50 kW fire burns about 3.9 kg of LPG an hour, or about 2 m³ an hour of gas. The arrestor has to pass that at your line pressure, with little pressure loss. Ask the maker for the figure on LPG, because datasheet charts are often for air.
What an arrestor can't do: it protects the pipe, not the pot. When the pot is first lit, it holds air, and gas and air can mix inside it. A flame getting back through the mat could make a sharp pop in the pot, and an arrestor upstream wouldn't stop that. Test lighting on the ground, at low flow, standing well clear. If it pops, stop and work out why before going further.

Other safety options, most useful first

OptionWhat it doesDo we need it?
Emergency ball valveOne quarter-turn stops the gas, within reach of whoever watches the fireYes, in the design
Regulator with hose-burst safetyCuts flow if the hose fails. The L-323 has this.Yes, in the design
Soapy leak testFinds leaks at every joint after any changeYes, every time
Flame-failure valveShuts the gas if the flame goes out, so gas can't keep poolingStrongly recommended. Otherwise someone must stay at the valve.
Gas solenoid with a stop button and key switchA valve that closes when power is cut, so it fails shut. Stop button away from the fire, key to stop anyone else lighting it.Good for shows and any crowd. Use one rated for LPG.
LPG leak alarm at ground levelLPG is heavier than air and pools low. The alarm warns near the cylinders.Cheap, and worth having
Non-return valve on each cylinderWith two cylinders joined, stops gas flowing from one into the other, and allows swaps while runningGood if you run two together
CO meter and alarmShows if the fire is short of air near peopleYes if there's any roof or cover over the dome
Dry-powder extinguisher and a cordonFire response by the cylinders, and a clear zone around the gasYes

Do we need a condensate drain before the bottles?

No. Don't fit any drain between the cylinder and the regulator. That part of the line is at full cylinder pressure, about 5–10 bar. Liquid LPG there would escape fast, turn to a large gas cloud and can freeze-burn skin.

1The gas line

Numbers match the parts table in section 4. Everything after the regulator runs at 0–20 psi.

    2Pipe size: how much flame each pipe can pass

    The bowl has no jet: gas goes straight from the copper into the bowl and leaves through the blanket. So the ground run and copper set the flow. With the regulator at a given pressure, this is roughly the most flame each size can feed. Estimated with the US gas code's (IFGC) high-pressure pipe formula for propane, to about ±30%.

    Find your flame size: weigh the cylinders, run the fire for an hour at your normal setting, and weigh them again. kW ≈ kg used per hour × 12.8. A Thai high-pressure regulator tops out at 5–6 kg/h (64–77 kW). Above that, use two regulators or an industrial one.

    Design choice: 20-bar LPG hose on the ground, copper up the riser

    The ground run is NCR LPG hose, rated 20 bar and marked มอก. 895, about 5–6 m from the regulator to the foot of the dome. You run it at 10–20 psi, so it has a big safety margin. Rules:

    Gas-rated PEX was considered but isn't sold in Thailand (it would mean importing pipe, fittings and a press tool) and is meant for fixed, buried lines, not a set that's packed away between shows.

    With no jet in the bowl, a bigger pipe makes the regulator knob more sensitive: with 3/8" copper, a tiny turn makes a big change in flame. If you upsize, keep a 1/4" ball or needle valve at the bottom of the riser to trim it.

    3Cylinders: cold, pressure, and the water bath

    When LPG boils it pulls heat out of the cylinder. Draw hard and the cylinder chills, frosts, and the pressure falls until the regulator can't hold its setting. Butane suffers most: it barely boils below 0 °C.

    I couldn't confirm the Thai cooking-gas mix. A forum post quoting PTT says 70% propane, but refinery LPG can be mostly butane. The chart shows both. As a cylinder empties, the propane boils off first, so the last third behaves like the butane-rich case.

    Water bath rules

    • Plastic tub or a cut-down drum, about 150 L for two 15 kg cylinders, upright. Water up to about two-thirds height. Keep the valve, the regulator and the safety relief valve (on the cylinder shoulder) dry and above water.
    • Start with tap water or warm water, at most about 40 °C. Never heat the tub or cylinder with a flame, heater, element or hot plate. Top it up with warm water during a long night instead.
    • Take the cylinders out and dry them afterwards. Thai gas shops refuse badly rusted cylinders.
    • Swapping to two 48 kg cylinders also helps a lot: more steel surface and more liquid to give up heat.

    How long a 50 kW flame holds at 10 psi

    15 °C night, cylinders half full. Rough heat-balance estimate.

    70% propane (PTT figure)30% propane (butane-rich)

    Does liquid form in the line? (dew point after the regulator)

    Propane in the gas coming offLine at 4 psiLine at 10 psiLine at 20 psi
    80%−21 °C−14 °C−5 °C
    60%−12 °C−4 °C+6 °C
    40%−5 °C+3 °C+13 °C
    20% (butane-rich)+1 °C+9 °C+19 °C

    Liquid forms where the pipe is colder than this. Propane boils off first, so the gas gets more butane-rich as a cylinder runs down. Pai's coolest nights are around 8–12 °C, so at 20 psi with a low cylinder, liquid in the line is a real possibility. Use the drip leg, and lower the pressure on cold nights or when a cylinder is getting low.

    Calculated from propane and butane vapour pressures, assuming an ideal mix. Treat these as a guide: they replace an earlier table on this page that read about 11 °C too low.

    Drip leg: catching liquid in the line

    You don't need a separate condensate line. Build the gas line so any liquid runs to one low point, and catch it there in a short capped stub.

    Why it's in the design

    • Liquid can reach the bowl. A slug of liquid gas boils suddenly when it reaches the heat, and that can cause a flare-up over people's heads.
    • It can block the flow. Liquid sitting in a dip makes the flame pulse or fade.
    • Dirt collects there too, rather than ending up in the valve or the mat.
    • Cold makes it more likely. So do high pressure and a nearly empty cylinder. The table above shows the temperatures.

    Building it

    1. Fit a tee at the lowest point of the line, at the foot of the riser.
    2. Point a brass nipple, 1/4" × 100 mm, straight down from the tee, with a brass cap on its end.
    3. Lay the hose with a steady fall from the regulator to the tee, with no dips. Fix it so it can't sag.
    4. Run the copper upward all the way from the tee to the bowl, with no dips.
    5. Leak-test the tee, nipple and cap with soapy water.

    Checking and draining it

    1. Check it after cold nights, and before the first burn of the day.
    2. Close the cylinder valves and burn the line empty, or vent it safely outdoors. Make sure there's no flame or spark nearby.
    3. Wear gloves and eye protection, as liquid gas can freeze-burn skin. Stand to one side.
    4. Loosen the cap slowly, and let any pressure and liquid escape outdoors.
    5. Refit the cap, then leak-test it before lighting.
    If you often find liquid: lower the line pressure, replace low cylinders sooner, and open the trim valve a little to keep the flame size. Never fit a drain between the cylinder and the regulator.

    Gas connection on the bowl

    The last metre of pipe is the hottest and hardest to reach, so it's all metal. Open the in-depth guide for every part, joint and test.

    In depth: the gas connection on the bowl

    Every joint, from the riser to the pot

    #PartJoined bySeal withNever
    1Copper riser, 3/8", clipped within 300 mm of the bowlFlare nutMetal to metal, with a drop of oil on the flare's backTape or sealant on the flare cone
    2Flare union, your disconnect pointTwo spannersMetal to metalTurning the pipe with the nut
    3Ball valve, brass, metal-seated if possible, out of direct flameFlare or threadLPG thread sealant on threadsPlastic-handled valve in the heat path
    4Braided stainless hose, optional, gives some flexFlare endsMetal to metalRubber hose, or braid touching hot steel
    5Brass adaptor, 3/8" flare × 3/8" BSPThread into the couplingLPG thread sealant rated for the temperatureMixing thread types, or overtightening into a thin weld
    6Half coupling, stainless 3/8" BSPFull TIG weld onto the potThe weldGalvanised fittings, or tack welds only
    7Pot top, with a 12 mm holeReinforcing pad if under 1.2 mmWeldDrilling with swarf left inside

    Which way it enters

    • From the top, in the middle, so gas spreads evenly across the mat.
    • Bend the copper gently into a loop before the bowl. It lets the pipe move as the bowl heats, so the weld doesn't take the strain.
    • Keep the union and valve to one side, where a spanner fits and the flame doesn't reach.
    • Let the pipe rise all the way, so liquid can't sit near the bowl.

    Heat limits to check on the first burn

    • Measure the fitting, valve and hose with a contact thermometer, at full fire, after 30 minutes.
    • Compare them with each part's rating. Thread sealants vary widely, so read the label.
    • If anything is close to its limit, add distance or a heat shield, or move that joint further from the bowl.
    • Soft-seated ball valves are the usual weak point, so fit them furthest from the heat.

    Assembling it

    1. Weld the coupling to the pot and clean out any metal bits before fitting the pot. Blow it through.
    2. Test the weld before fitting. The safest check is a dye-penetrant kit on the weld. If you air-test instead, clamp the pot's open base to a board with a gasket and use no more than about 0.5 psi (35 mbar), through a low-pressure regulator, standing clear. Then brush the seams with soapy water. Higher pressure can throw the board off: 5 psi pushes on it with about 200 kg of force.
    3. Screw in the adaptor with sealant. Hold the coupling side steady, and don't force it.
    4. Slide on the flare nuts before flaring. Cut square, remove the burr, and flare. A good flare is smooth and even, with no cracks.
    5. Tighten flare joints with two spanners. Air-con guidance for 3/8" flares is about 33–40 N·m, so check it for your fittings.
    6. Fix the clips, then check that nothing pulls on the pot.

    Testing it

    1. The bowl can't hold pressure, because gas is meant to leave through the mat. So test the pipe with the bowl's ball valve closed.
    2. Pressure the line to 20 psi, then close the cylinder and watch the gauge for 10 minutes. It should hold steady.
    3. Brush every joint with soapy water, up to the closed valve. Bubbles mean a leak.
    4. On the first low burn, brush the joints past the valve too, and look for flame at the fitting. Keep soap away from hot metal, and let it cool first if needed.
    5. Check again after the first few hot and cold cycles, as joints can loosen.

    If something's wrong

    You seeLikely causeWhat to do
    Bubbles at a flarePoor flare or loose nutGas off. Tighten a little. If it still leaks, recut and reflare. Don't add tape.
    Bubbles at the threadWrong thread or poor sealGas off. Check the thread type, clean it and reseal.
    Flame or soot at the weldCrack or pinholeGas off, cool it, and have it rewelded. Never burn with a leaking weld.
    Pot top bending, or fitting movesPipe pulling, or wall too thinSupport the pipe and add a pad, or use a thicker bowl.
    Flame pulses or spitsLiquid in the lineGas off. Check the drip leg and any dips, and lower the pressure.

    Disconnecting the bowl

    1. Close the cylinders, and let the flame burn out the gas left in the line.
    2. Close the bowl's ball valve and let everything cool.
    3. Undo the flare union with two spanners, and cap both open ends.
    4. After refitting, leak-test the union, and let gas purge the air from the line, away from any flame, before lighting.

    More on fitting choices and welding is on the Pot & fitting tab.

    Moving the fire: extending the gas line

    To make the placement adaptable, keep the two ends fixed and change only the middle. The cylinder and regulator board is one fixed unit. The riser and bowl stay with the canopy. Between them, use ready-made hose sections in set lengths.

    Ways to extend it

    OptionHow it worksGood and badOur view
    Set hose sections with metal unionsLPG hose in 3, 5 and 10 m lengths, each with factory or crimped ends, joined by threaded or flare unionsSecure and low cost. A joint takes a minute with two spanners, and each must be leak-tested.Recommended
    Sections with self-sealing quick couplersSame sections, with gas-rated couplers that shut when pulled apartFastest, and each end seals itself. Costs more and restricts flow more. Hard to find online in Thailand.Good upgrade for one regular join
    A longer hose on a reelOne long hose, with the extra stored on a reelNo extra joints. Pressure drop stays the same however short the move, and a coil can overheat or get damaged.Fine for small moves
    Fixed copper or steel extensionsRigid pipe with flare unionsTough, but heavy to move, and repeated bending can crack copper.Only for a long-term location
    Hose clamps or plastic push-fit joinersBarb joiner or plastic connectorQuick and cheap, but easy to damage, and not meant to be taken apart again and again.Don't use for extensions

    How long can it go?

    Rules for every setup

    • Use as few joints as you can. Pick the shortest section that reaches, and don't add spares in the line.
    • Keep the drip leg at the lowest point. If a new layout has a lower dip, move the drip leg there or re-lay the hose so it falls to the tee.
    • Protect the hose. Keep it in conduit or ramps anywhere people walk or vehicles drive, and out of the heat.
    • Keep the cylinders away from the fire and crowd, somewhere upwind with room to reach the valve. Fence them off.
    • Cap every open end when stored, so dirt and insects can't block the line.
    • Label each section with its length, last test date and any damage. Throw out cracked or cut hose.

    Each time you move it

    1. Close the cylinders, and burn the gas out of the line.
    2. Undo only the section joints. Leave the board and riser joints alone where possible.
    3. Lay out the new route, falling to the drip leg, with no dips.
    4. Join and tighten the sections. With the bowl valve shut, bring the line up to 20 psi with gas, then soap-test every joint and watch the gauge for 10 minutes.
    5. Purge the air out with gas, away from any flame, then light at low flow.
    6. Reset the trim valve if the line length has changed.

    4Parts and where to buy them

    Budget is the cheapest thing that works. Recommended is what I'd buy. Search terms are in Thai for Lazada, Shopee or the shop counter. HomePro, Thai Watsadu, Global House, Mega Home and Makro all have Chiang Mai branches.

    What a kit costs

    Totals from the table above, using the middle of each estimate. Tools are a one-off cost.

    Gas partsDiffuser (blanket, mesh, holder)Tools

    5Fire blanket: what survives in the flame

    The cloth sits right in the flame and glows at about 900–1,200 °C (orange line). Only cloth rated near 1,000 °C continuous lasts. It's a ceiling, so anything it sheds falls on people.

    continuous useshort-term maximumcloth temperature in the flame
    Pure Kevlar won't work as the diffuser. Kevlar is a protective fabric: it doesn't melt and it puts itself out when the flame is taken away. But it is only rated to about 150–180 °C continuous and starts to decompose at about 425 °C. In this flame it would char and burn through within minutes, giving off hydrogen cyanide and carbon monoxide. Good places for Kevlar on this build: gloves, a heat sleeve over the gas hose, or a welding curtain.

    Recommended: uncoated 96% silica cloth, two layers, cut about 60 mm bigger than the opening. Uncoated cloth goes straight on. Silicone-coated cloth also works, but the coating smokes off the first time it's heated, so do that first burn outdoors. Treat the cloth as a part you replace each season. It goes brittle after many heat cycles.

    Worth testing first: two or three layers of heavy stainless mesh, or a laser-cut perforated plate, with no cloth at all. It may spread the flame well enough and sheds nothing.

    6Bolted blanket holder (a cassette)

    The cloth, mesh and support grid are clamped as one cassette to studs on the top plate, not to the bowl. The aluminium bowl then carries no load. You can change the blanket from below without touching the gas or the bowl.

    1. Studs: 6 × M8 stainless studs, welded to the underside of the top plate on a Ø 380 mm circle, pointing down 40 mm.
    2. Seal: a strip of silica cloth or 3 mm ceramic tape around the opening.
    3. Blanket: 2 layers of silica cloth, Ø 360 mm.
    4. Mesh: heavy 304 or 310S stainless mesh, Ø 360 mm, wire at least 1.2 mm with a 6–12 mm opening.
    5. Support grid: a 5 mm stainless ring (OD 420, ID 300) with 6 spokes of 20 × 3 mm flat bar welded across it on edge, so the mesh can't sag into the flame.
    6. Keyhole slots in the ring and stainless wing nuts with copper or nickel anti-seize. To remove: loosen the six nuts half a turn, turn the ring 15° and lower it.

    Keep two cassettes made up, and swap them on the ground. Instead of the mesh and spokes, a laser shop can cut one 2–3 mm 304 diffuser plate with 6–8 mm holes (about 40% open) in a pattern of your choice (section 7).

    Mesh and fasteners

    OptionHeat limit in air, intermittent / continuousNotesThai sourceTHB
    310S stainless mesh1,035 / 1,150 °CThe right grade for parts sitting in the flameNot stocked in Thailand. AliExpress / Alibaba700–2,100 /m² + shipping
    304 stainless mesh, heavy (1.2+ mm wire)870 / 925 °CFine for a season, then replace. Thin 0.5 mm screen burns through in weeksLazada 304 mesh · ตะแกรงสแตนเลส 304300–800 /m²
    Laser-cut 304 plate, 2–3 mm870 / 925 °CMesh and support in one piece. Can carry a pattern. Keep holes at least as wide as the plate is thickTK Stainless or Saengphet (section 7)600–1,500 each
    M8 A2 stainless studs + wing nuts ×6about 500 °CKeep them outside the flame, on the ringAny fastener shop · สตัดสแตนเลส, น็อตหางปลาสแตนเลส100–250
    Copper anti-seize spray (CRC, 982 °C)—Stops hot stainless threads seizingLazada CRC · จารบีกันติด300–450
    Graphite gasketburns from ~450 °CNot at the opening. Use silica cloth or ceramic tape instead——

    7Laser cutting in Chiang Mai

    Yes, there are fiber-laser shops. None of their listings give machine size or prices, so phone or message them on LINE with the DXF from the planner. Ask four things:

    1. Laser power and bed size (a 1500 × 3000 bed takes your 2440 × 1220 sheets whole).
    2. Do they take DXF over LINE?
    3. Do they supply SS400 / 304 sheet, or cut yours?
    4. Can they also fold?
    ShopWhereContactKnown
    Saengphet Metal Products
    บริษัท แสงเพ็ชร โลหะภัณฑ์
    123 Moo 1, Saraphi, Route 11 toward Lampang089-433-1792
    053-963-138
    Laser and waterjet cutting, shearing, press brake, rolling. Steel, stainless and aluminium. Lists perforating and pattern cutting. Mon–Sat 8–17
    TK Stainless Steel
    ที.เค. สแตนเลสสตีล
    117/37 Superhighway CM–Lampang, Pa Tan053-216-581
    081-929-5215
    FB: TKSTAINLESSSTEEL
    Stainless fabricator, cut and fold, laser pattern cutting (ฉลุลาย). Best for the 304 diffuser plate and cassette
    Openwork steel doors (laser-cut gates)Saraphi / Mae Ka098-796-8539Makes decorative laser-cut steel gates, so almost certainly has a fiber laser (unconfirmed)
    Chiang Mai Laser EngravingSan Kamphaeng Rd053-339-393
    081-882-7390
    Mostly engraving. Thin metal only, probably
    Guenter (Bangkok, ships nationwide)Nong Chok, BangkokLINE @guenter.th12 kW fiber laser, mild steel up to 40 mm, takes DXF, no minimum order, press brake. Fallback if Chiang Mai can't do it

    Price guide (a Bangkok shop's published table, cutting only): mild steel about ฿40–50 per metre of cut for single pieces (1–3 mm), stainless about ฿40–80/m. It drops a lot for 50+ pieces. The canopy is about 23 m of cut, so roughly ฿1,000–1,500 plus steel. For patterns, every hole is a pierce, and dense patterns can add ฿1,000–3,000+ per panel.

    Patterns in the canopy: the canopy is what keeps flame and hot gas off the galvanised dome struts and the gas line. Holes let both through. Keep cut patterns to the skirt and the lower half of the roof panels, nowhere near the top plate, the riser or the dome hub above it.

    8Tools for joining the pipe

    Flared copper joints are the easiest: no flame, they can be undone, and the tools are sold everywhere. Brazing is stronger but needs a torch, silver rod and practice. Use flare for this.

    ToolBudgetBetterThai term
    Flaring tool kit (1/4"–3/4")"PROFESSIONAL" 10-piece, ฿1,299 (HomePro)TASCO Black TB550FC, ฿4,159 (HomePro)ชุดบานแป๊ป
    Tube cutterVALUE VTC-19, ฿140 (HomePro)TASCO TB20T, ฿429 (HomePro)คัตเตอร์ตัดท่อทองแดง
    Tube bender (1/4, 5/16, 3/8)GIANT KINGKONG SATB01, ฿198 (Thai Watsadu)WORKPRO WP303004, ฿313 (Thai Watsadu)เบนเดอร์ดัดท่อทองแดง
    Deburring tool, 2 spanners (14/17/22 mm)฿150–400, often in the flaring kitตัวลบคมท่อ, ประแจ
    Thread tape for gas (threaded brass only, never on flares)SCG PTFE ฿27–35. Yellow gas-grade tape ฿40–80เทปพันเกลียวแก๊ส
    Leak testSoapy water in a spray bottle. Never test with a flameน้ำสบู่

    9Gas shops in Chiang Mai

    ShopSellsContactWhere
    Khuang Singha Gas
    ข่วงสิงห์แก๊ส
    Cylinders, commercial burners, gas piping. Ask for the L-323, quick coupler and braided hose053-212-827
    089-555-6121
    LINE 0895556121
    218/2-4 Chang Phueak Rd. Mon–Sat 7–18
    Jang Yong Heng SengTools, brass fittings, copper pipe, welding gear053-241-136
    LINE jyh8185
    81–85 Charoen Mueang Rd, Wat Ket. Mon–Fri 8–17
    Chiang Mai Air Care EngineeringCopper tube, flaring and bending tools064-624-9296
    LINE @AIRCARE
    Ton Pao, San Kamphaeng. Mon–Sat 8–17
    Mae Hia Gas CenterGas equipment053-447-537
    086-730-7137
    Rd 108 (Hang Dong Rd). Daily 7–19
    Soonthorn Gas (ships nationwide)Regulators, hoses, fittings089-199-1919
    LINE @soonthorngas
    Mail order

    Phone numbers come from directory listings and haven't been checked. Messages in Thai, ready to paste into LINE, are in thai-fixer/jobs/fire-umbrella-parts.md.